Technical Specifications of SolarTile
Overview of SolarTile Technical Details
Product Dimensions & Weight Information
Overview of SolarTile Technical Details
- Complete Unit: 770 x 422 x 32 mm (9.3 kg)
- Base Unit: 731 x 418 x 30 mm (4.1 kg)
- Solar Top: 731 x 411 x 31 mm (5.2 kg)
- Headlap: 75 mm (Min) & 85 mm (Max)
- Cable Bend Radius: 33 mm (Min)
- Batten Size (Typical): 25 x 50 mm
- Effective Exposed Area: 0.25m²
- Gauge: 337 mm (Min) & 347 mm (Max)
- Free Cable Length: 870 mm
- Cable Diameter: 6.6 mm
- Roof Pitch: 22.5° (Min) & 60° (Max)
- Battens Required: 3m/m²
Summary of the Solar Panel’s Electrical Performance
- Cell Type [P402]: Monocrystaline
- Output (peak wattage): 30 Wp
- Output /m²: 120 Wp/m²
- Short Circuit Current: 8.8 A
- Open Circuit Voltage: 4.9 V
- Max. System Voltage: 600 V
- Current at Max. Power: 7.63 A
- Voltage at Max. Power: 4.00 V
- Current temperature Co-Efficient at Short Circuit: +2.5 mA/°C
- Voltage tempearature Co-Efficient at Open Circuit: -16.96mV/°C
- Power temperature Co-Efficient at Max Power: -0.43 %/°C
- Cable/Connectors: Class 5 Double Insulated
Other Information
Additional Information on the SolarTile
Fixings [P415]
Philips size 3, 1/4 turn 15 mm rapier stud. Tamper-proof fixings available on request.
Materials of Construction
Halogen free fire retardant thermoset composite (base and panel surround). Toughened glass (panel).
Tile Clearance
While roofing felt is used, a minimum clearance of 25 mm below the tile is advised, plus adequate ventiliation at the eaves and the ridge. e.g. counter battening.
Traceability
Each panel is marked with a unique traceable serial number.
International Standards
- IEC 61215 Approved
- IEC 61730 Approved
- BRE MCS Microgeneration Approved – Reference No. MCS PV0014/01
System Sizing | ||
No. Tiles | Area m² | Output kWp |
20 | 5 | 0.61 |
40 | 10 | 1.22 |
60 | 15 | 1.83 |
80 | 20 | 2.44 |
100 | 25 | 3.05 |
SolarTile Partners & Associations